Noise, boiler exhaust, unorganized waste gas, sewage treatment station exit detection
Table 3 unit of noise detection in the factory: dB (A)
Monitoring point position
Monitoring date
Daytime noise
Nocturnal noise
For the first time
The second time
For the first time
The second time
1#
2017.12.4
Fifty-three point four
Fifty-three point six
Forty-eight point three
Forty-eight point seven
2#
Forty-nine point three
Forty-eight point eight
Forty-six point nine
Forty-six point three
3#
Forty-nine point seven
Forty-nine point one
Forty-six point eight
Forty-six point nine
4#
Fifty point one
Fifty point nine
Forty-seven point five
Forty-seven point six
Boiler exhaust gas test results (sampling date: 2017.12.4)
Detection project
Company
detection result
For the first time
The second time
Third time
SO2
Measured concentration
Mg/Nm3
Three
Three
Four
Conversion concentration
Mg/Nm3
Eight point two
Seven point eight
Nine point six
Emission
Kg/h
Zero point zero five six
Zero point zero five nine
Zero point zero six eight
NOX
Measured concentration
Mg/Nm3
Forty
Forty-two
Forty-four
Conversion concentration
Mg/Nm3
Eighty-one point eight
One hundred and nine point six
One hundred and five point six
Emission
Kg/h
Zero point five six
Zero point eight three
Zero point seven five
smoke
Measured concentration
Mg/Nm3
Nine point five
Nine point six
Nine point eight
Conversion concentration
Mg/Nm3
Twenty-five point nine
Twenty-five point one
Twenty-three point five
Emission
Kg/h
Zero point one eight
Zero point one nine
Zero point one seven
Exhaust volume
Nm3/h
Six thousand eight hundred and twenty-eight
Seven thousand five hundred and forty-four
Seven thousand one hundred and two
oxygen content
%
Sixteen point six
Sixteen point four
Sixteen
Smoke temperature
Centigrade
Fifty-two
Fifty-two
Fifty-one
Chimney height
M
Twenty
Chimney diameter
M
Zero point four
Remarks: converted emission concentration = measured emission concentration * (21- reference oxygen content) / (21- measured oxygen content).
The reference oxygen content (%) of coal fired boiler is 9.
Unorganized exhaust gas detection results
Detection point
time
Detection project
Particulate matter (mg/m3)
For the first time
The second time
Third time
Factory area
2017.12.4
Upwind to 1#
Zero point one six
Zero point one three
Zero point one five
Downwind to 2#
Zero point two two
Zero point one nine
Zero point two two
Downwind to 3#
Zero point one nine
Zero point two one
Zero point two one
Downwind to 4#
Zero point one eight
Zero point one seven
Zero point two one
Export test results of sewage treatment station
Date of detection
frequency
Detection project
CODCr
BOD5
SS
ammonia nitrogen
PH
2017.12.04
For the first time
Forty-three point one
Six point three
Fourteen point eight
Seven point seven
Seven point one
The second time
Forty point two
Five point six
Fifteen point six
Six point eight
Seven point one
Third time
Thirty-nine point six
Five point one
Thirteen point nine
Seven point three
Seven point two
Fourth times
Forty-one point six
Five point three
Fourteen point eight
Seven point one
Seven point one
GREAT INNOVATION PHARMA
Address : No.588 Zixing Road,Zizhu National High-tech Industrial Development Zone, Minhang , Shanghai China
Zip code: 200241
Tel:8621-51143139 / 31229518
Fax:8621-57747216 / 69517800
Website:www.gipharma.com.cn
E-mail:sales@gipharma.com.cn
Copyright © 20011-2016,www.gipharma.com.cn ,All rights reservedCopyright © GIP Group Co., Ltd. strictly prohibit copying words without permission.